4-Channel Leak Detection Control Module

관리자 2026.02.16 20:21:16 Subtitle: 4-Channel | For Solvent & Oil Sensors (RS-485 / Modbus) Model: YHSM-04S-A
Yoohantech 4-Channel Solvent & Oil Leak Detection Control Module YHSM-04S-A

💡 Key Summary: 4-Channel Leak Detection Control Module for Solvent & Oil, Managing Up to 4 Zones at Once

YHSM-04S-A is a 4-channel leak detection control module designed for YHSP-SA and YHSP-SA-Ex leak point sensors, supporting up to four sensors. It provides real-time leak monitoring, LCD status display and user-adjustable sensitivity. Relay outputs include two contacts per channel and four common contacts. RS-485 (Modbus RTU / YH-BUS) supports host system integration. An MTL7760ac Zener barrier is required when connecting YHSP-SA-Ex in an intrinsically safe system.

4-Channel | For Solvent & Oil Sensors (RS-485 / Modbus RTU / YH-BUS)
YHSM-04S-A
YHSM-04S-A

YHSM-04S-A: A 4-Channel Control System for Integrated Management of Multiple Detection Points

Separate and Manage Solvent & Oil Leak Detection Zones by Channel

For sites with multiple detection points, YHSM-04S-A supports four-channel leak monitoring and host system integration. YHSM-04S-A 4-Channel Leak Detection Control Module connects up to four YHSP-SA or YHSP-SA-Ex leak point sensors for organic solvents and oils. It provides LCD monitoring, adjustable channel sensitivity and NO / NC relay outputs, with RS-485 communication for PLC, DCS and SCADA systems.

Key Features

⚡️ 4-Channel Leak Monitoring & Alarm Output

• Supports up to four leak point sensors and provides NO / NC relay outputs for leak alarm signaling.

• Provides real-time leak monitoring and control through one 4-channel module.

🔗 Compatible Sensors & System Configuration

• Designed for YHSP-SA and YHSP-SA-Ex leak point sensors for organic solvents and oils.

• An MTL7760ac Zener barrier is required for an intrinsically safe system using YHSP-SA-Ex.

🖥️ Integrated LCD Monitoring & Field Configuration

• View operating status and settings on the LCD (60×33mm).

• Adjust sensitivity for each channel to match site conditions.

⚙️ Per-Channel / Common Contacts & Monitoring Integration

• Provides 2 relay contacts per channel and 4 common contacts for alarm and control integration.

• Supports RS-485 communication with Modbus RTU and YH-BUS protocols for integration with PLC, DCS and SCADA systems.


"From four-channel leak monitoring to relay outputs and host system integration,
YHSM-04S-A supports up to four compatible point sensors for organic solvent and oil leak detection."

Detection Targets & Compatible Sensors
Model Type Detection Targets
YHSP-SA Electronic Leak Point Sensor | For Solvent & Oil Organic solvents and oils. (Up to 4 compatible sensors per module)
YHSP-SA-Ex Intrinsically Safe Electronic Leak Point Sensor | For Solvent & Oil; MTL7760ac Zener barrier required
Specification
Item Specification
Model YHSM-04S-A (4-Channel Leak Detection Control Module)
Number of Channels 4 Channels
Supported Sensors YHSP-SA / YHSP-SA-Ex Leak Point Sensors
Sensor Capacity Up to 4 Sensors
Detection Method Level Shift
Display 60 × 33 mm LCD Status Display
Power Input DC 24 V (±10%)
Power Consumption Max. 3 W
Power Indicator Power status indicator (PWR)
Alarm Output • Relay Outputs (NO / NC) for leak alarm signaling
• 2 relay contacts per channel and 4 common contacts
Communication RS-485 (Modbus RTU / YH-BUS); 2-wire interface
Baud Rate 9,600 / 14,400 / 19,200 / 38,400 / 57,600 / 115,200 bps
Maximum Communication Distance Up to 1,200 m depending on cable type
Operating Temp / Humidity -20 to +60 °C / 10 to 90% RH (non-condensing)
Storage Temperature -30 to +70 °C
Materials ABS, PC, Aluminum
Mounting Panel Mount
Dimensions (W×H×D) 94 × 178 × 32 mm
Weight Approx. 500 g
Key Functions • Sensor capacity: up to four YHSP-SA or YHSP-SA-Ex leak point sensors
• LCD monitoring: integrated viewing of settings and status via LCD (60×33mm)
• Sensitivity adjustment: user-adjustable settings for each channel
• External communication: RS-485 (2-wire) interface to PLC, DCS and SCADA systems
• Protocols: Modbus RTU and YH-BUS (proprietary protocol)
• Intrinsically safe system: MTL7760ac Zener barrier required for YHSP-SA-Ex
• Relay contacts: 2 contacts per channel and 4 common contacts
* YHSP-SA-Ex requires an MTL7760ac Zener barrier. Refer to the User Manual for installation and wiring instructions.
📄

Product Downloads

📥 Download Brochure 📥 Download Datasheet
💧

Liquid Leak Detector: Technical Inquiry

We confirm applicability and recommend solutions based on your target liquid and site conditions.

✉️ Email Us 💬 Request Technical Consultation

Setting the trusted standard for liquid leak detection in industrial facilities.

Yoohantech Co., Ltd.