Leak Detection Tests

safety, driven by dedication, and delivering innovation.

Yoohantech Co., Ltd.
Organic Solvent Leak Detection Test | 15-Second Response for Non-Conductive Liquids (YHSP-SA)
Model
YHSP-SA
Substance Name
2-EHCL(OCL)
Chemical Formula
C8H15ClO
CAS No.
760-67-8
Substance Type
Organic Solvent

Video Review 3-Line Summary of the 2-EHCL (Organic Solvent) Leak Detection Test

  • 🧪 Test Model: Organic solvent sensor YHSP-SA
  • Detection Speed: Alarm within 15 seconds upon contact with 2-EHCL
  • 🚫 Water Response: No response even after more than 20 seconds in water (zero false alarms)

 

 

 

🔬 15-Second Response: Chemical Leak Detection Performance Test (2-EHCL vs Water)

 

In a quiet laboratory, every small movement matters. Today’s two key subjects are 2-EHCL (OCL), a hazardous organic solvent 🧪, and the advanced industrial leak detector, the YHSP-SA sensor 🛡️, designed to help prevent invisible leak incidents. This video is more than a simple test. It shows how a leak detection system helps protect safety in real industrial environments.

 

📊 Leak Detection Test Overview (Test Blueprint)

 

  • 🧪 Test Substance: 2-EHCL (OCL) from Dong Sung Chemical - Organic Solvent

  • 🤖 Core Equipment: Organic solvent point-type leak detector (YHSP-SA)

  • 🎯 Test Goals:

    • ✅ Verify high selectivity with no response to water, such as rainwater or condensation

    • ✅ Measure fast and accurate leak detection and alarm performance for the target chemical

 


 

🎬 Test Procedure: Verifying Leak Sensor Precision

 

 

Act 1: False Alarm Prevention Test - Contact with Water 💧

 

The first stage verifies the reliability of the leak detector. The sensor is quietly immersed in clean water to check whether ordinary moisture, rainwater, or pipe condensation could trigger a false alarm.

  • Result: The sensor remains completely silent in water for more than 20 seconds. 🤫 No false alarm is triggered. This is the first requirement of a high-performance leak detection sensor. Perfect! 👍

 

Act 2: Simulated Chemical Leak - Contact with 2-EHCL 🧪

 

Now it is time for the real target material. After the sensor is dried, it is exposed to 2-EHCL organic solvent. This simulates an actual chemical leak incident in an industrial environment.

  • Result: 5 seconds, 10 seconds, 13 seconds... the tension builds... and before 15 seconds, the system reacts strongly. 🚨 A sharp alarm and flashing warning light clearly announce the danger, proving that the leak detector has performed its mission successfully.

 


 

🌟 Final Conclusion: 15 Seconds of Golden Response Time

 

  • 🔢 Initial Sensor Value: 1.0315

  • 📈 Alarm Threshold: 2.03

  • ⏱️ Time to Alarm: Within approximately 15 seconds

Fifteen seconds is not just a number. It represents valuable golden response time that can help minimize damage and improve safety when a chemical leak occurs. ⏳➡️👨‍🚒

This video shows that the YHSP-SA sensor is more than a simple device. It is an intelligent leak detector that identifies chemical leaks quickly and responds with confidence. It remains stable in water while delivering fast warning performance when exposed to hazardous materials. This is Yoohantech’s leak detection technology in action.

Designing industrial safety through technology. ✨🛡️

 

💧

Liquid Leak Detector: Technical Inquiry

We confirm applicability and recommend solutions based on your target liquid and site conditions.

✉️ Email Us 💬 Request Technical Consultation