Aluminum Paste Leak Detection Test Using the YHSP-SA Leak Detection Sensor | 20-Second Detection Response

Admin 2026.06.19 14:27:47 Model: YHSP-SA Substance Name: Aluminum Paste Chemical Formula: Al CAS No.: 7429-90-5 Substance Type: Organic Solvent
Aluminum paste leak detection sensor test using Yoohantech YHSP-SA Electronic Leak Point Sensor. This industrial chemical leak detection test verifies no false alarms in water and confirms aluminum paste detection within approximately 20 seconds. Suitable for leak detection sensor, chemical leak detection, organic solvent leak detection, industrial leak detector, chemical spill monitoring, and process safety applications.

Technical Note | Aluminum Paste Leak Detection Test

This video demonstrates an industrial leak detection sensor test using aluminum paste and the YHSP-SA Electronic Leak Point Sensor. The test verifies no false alarms in water, reliable organic solvent detection, and successful alarm activation within approximately 20 seconds.

Aluminum Paste Leak Detection Test Using the YHSP-SA Electronic Leak Point Sensor

Yoohantech continuously conducts leak detection performance tests using real industrial chemicals to verify sensor reliability, response characteristics, and practical field performance.

This test evaluates the leak detection capability of the YHSP-SA Electronic Leak Point Sensor using aluminum paste provided by Korea Camtech.

Test Overview

Water Response Verification

Before testing the aluminum paste sample, the sensor was immersed in water for approximately 30 seconds to verify whether any false alarm would occur.

The sensor showed no response and no alarm activation during the water test.

This demonstrates the sensor's ability to distinguish water from target chemicals and prevent false alarms caused by moisture, condensation, or rainwater.

Aluminum Paste Leak Detection Test

After removing moisture from the sensor surface, the sensor was immersed in the aluminum paste sample and the response time was measured.

The sensor reading increased from the initial value of 1.05 and reached the preset alarm threshold of 2.10 in approximately 20 seconds.

Once the threshold was reached, the alarm was activated immediately, confirming reliable leak detection performance.

Test Results

Key Features of the YHSP-SA Leak Detection Sensor

Conclusion

This test confirms that the YHSP-SA Electronic Leak Point Sensor can reliably detect aluminum paste while maintaining immunity to water-induced false alarms.

The successful detection of aluminum paste within approximately 20 seconds demonstrates the sensor's suitability for industrial leak detection, chemical spill monitoring, and process safety applications.

 

💧

Liquid Leak Detector: Technical Inquiry

We confirm applicability and recommend solutions based on your target liquid and site conditions.

✉️ Email Us 💬 Request Technical Consultation

Setting the trusted standard for liquid leak detection in industrial facilities.

Yoohantech Co., Ltd.