Intrinsically Safe Electronic Leak Point Sensor

관리자 2026.02.16 18:40:37 Subtitle: For Organic Solvents & Oils | Controller Module Required | KCs Certified Model: YHSP-SA-Ex
Yoohantech YHSP-SA-Ex Intrinsically Safe Electronic Leak Point Sensor (For Organic Solvents & Oils, KCs Certified)
No Response to Water Optimized detection by chemical family for organic solvents and oils.

💡 Key Summary: Intrinsically Safe Electronic Leak Point Sensor – For Organic Solvents & Oils

YHSP-SA-Ex is an intrinsically safe electronic leak point sensor designed for chemical-family specific detection of organic solvents and oils on-site. Its Ex ia intrinsically safe design (Ex ia IIC T6, KCs certified) is suitable for hazardous areas when used in an intrinsically safe circuit. It detects organic solvents and oil-based chemicals without responding to water. Response time is 2 to 60 seconds, depending on the chemical. The replaceable YHS-FS floor sensor cartridge allows the sensor body to remain installed, supports quick field replacement and reduces maintenance costs.

For Organic Solvents & Oils | Optimized Detection by Chemical Family | Controller Module Required | KCs Certified

YHSP-SA-Ex

 

🛡️ KCs Intrinsically Safe Certification | Ex ia IIC T6

Chemical-family specific detection for organic solvent & oil leaks, without responding to water

YHSP-SA-Ex: chemical family detection, fast response and a replaceable sensor cartridge

Detects leaks within 2 to 60 seconds, depending on the chemical. The YHSP-SA-Ex intrinsically safe electronic leak point sensor detects organic solvents and oils without responding to water and operates with the required MTL7760ac Zener barrier and a compatible YOOHANTECH leak detection control module.

CORE FUNCTIONS

🔬 Optimized Detection by Chemical Family (Organic Solvents & Oils)

• Designed for chemical-family specific detection of organic solvents and oils without responding to water. Typical detection media include THF, acetone, IPA, toluene, MEK and xylene.

🔧 Replaceable Sensor Cartridge (Cost Saving)

• The YHS-FS floor sensor cartridge is replaceable while the sensor body remains installed. This supports quick field replacement and reduced maintenance costs.

🛡️ Intrinsically Safe Design (Ex ia)

• KCs-certified Ex ia IIC T6 design is suitable for hazardous areas. Use the sensor only in an intrinsically safe circuit.

💡 Control Module Integration

• Operates with the MTL7760ac Zener barrier and a YOOHANTECH leak detection control module. Select either YHSM-01S-A (1 channel) or YHSM-04S-A (4 channels).


⚙️ Intrinsically Safe Leak Detection System Configuration (System Configuration)

• Intrinsically Safe Ex ia Protection

Use the sensor only in an intrinsically safe circuit. KCs intrinsic safety certification: Ex ia IIC T6, Certificate No. 25-AV2BO-0187X. Refer to the YHSP-SA-Ex Sensor Wiring Guide for detailed wiring instructions.

• Required System Components

The YHBK-P02 protective housing, YHWS-P02 grounding and positioning base, and MTL7760ac Zener barrier are required. Use either a YHSM-01S-A (1-channel) or YHSM-04S-A (4-channel) leak detection control module.

📄

Product Downloads

📥 Download Brochure 📥 Download Datasheet
🎥

Watch Real Leak Detection Test Videos

View test footage verified under real leak conditions, including sensor response and alarm operation.

▶️ View Leak Test Videos
TECHNICAL SPECIFICATIONS
Item Details
Model YHSP-SA-Ex
Operating Voltage DC 2.5 V
Measurement Range • A1: 0 ~ 100.0 MΩ
• A2: 0 ~ 60.00 MΩ
• A3: 0 ~ 6.000 MΩ
Output Level Shift
Detection Media Organic solvents and oil-based chemicals, including NMP, MEK, toluene, and gasoline
Sensor Dimensions 68 × 68 × 32 (±0.5) mm
Overall Dimensions 178 × 80 × 34 (±0.5) mm
Materials SUS 304, PP, carbon, etc.
Operating Environment Around tanks and piping in industrial facilities
Suitable for indoor and outdoor use
Operating Temperature -20 to +55 °C
Response Time 2 to 60 seconds (depending on the chemical)
Typical Detection Media Oils, organic solvents, and VOCs: insulating oil, engine oil, OMCTS, tar oil, TDA, TDI, benzene, xylene, etc.
Sensor Wiring 2-wire sensor: White (+), Black (−)
Certification KCs Intrinsic Safety Certification — Ex ia IIC T6
Certificate No. 25-AV2BO-0187X
Certification Body: KOSHA
Intrinsic Safety Parameters Ui = 10 V; Ii = 200 mA; Pi = 0.5 W
Li = 0.4 mH (with 160 m cable)
Ci = 33.6 nF (with 160 m cable)
Ta: -20 to +55 °C
Key Points •  Chemical family detection: organic solvents and oil-based chemicals
• No response to water
• Control module integration: MTL7760ac barrier with either YHSM-01S-A or YHSM-04S-A
• Replaceable YHS-FS cartridge: sensor body remains installed; reduced maintenance costs
• Intrinsically safe design: Ex ia IIC T6; use only in an intrinsically safe circuit

Industry-Specific Leak Detection Proposals

Semiconductors · Petrochemicals · Oil Refining · Batteries · Power Generation · Steel · Warehousing · Wastewater Treatment · Defense

🏭

View Installation Case Studies

Explore real industrial leak detection installations and get guidance on a configuration that fits your facility.

✉️ Email Us 💬 View Case Studies

 

DIMENSIONS (Drawing)

dwg.png

 

REQUIRED COMPONENTS & REPLACEMENT PARTS

YHSM-01S-A

🔹YHSM-01S-A (1-Channel Leak Detection Control Module)

YHSM-04S-A

🔹YHSM-04S-A (4-Channel Leak Detection Control Module)

YHS-FS

🔹YHS-FS (Floor Sensor Cartridge — Replacement)

YHWS-P02

🔹YHWS-P02 (Grounding & Positioning Base — Required)

Zener Barrier

🔹MTL7760ac (Zener Barrier — Required)

YHBK-P02 Dedicated Protective Housing, YHWS-P02 Grounding & Positioning Base, and MTL7760ac Zener Barrier are required.
Select either the YHSM-01S-A (1-channel) or YHSM-04S-A (4-channel) control module.
YHS-FS is an optional replacement floor sensor cartridge.

 

💧

Liquid Leak Detector: Technical Inquiry

We confirm applicability and recommend solutions based on your target liquid and site conditions.

✉️ Email Us 💬 Request Technical Consultation

Setting the trusted standard for liquid leak detection in industrial facilities.

Yoohantech Co., Ltd.