safety, driven by dedication, and delivering innovation.
Surfynol TG leak detection, organic solvent leak detection, and industrial chemical leak monitoring are essential for safe operation in chemical handling and manufacturing environments. In this video, Yoohantech’s electronic point leak detection sensor is used to test detection performance for Surfynol TG and verify stable operation with no response to water.
In the first step, the sensor is immersed in water for approximately 60 seconds and shows no response. In the second step, the same sensor is exposed to Surfynol TG, and the alarm is triggered in less than 10 seconds. This test demonstrates that the YHSP-SA leak detector can distinguish the target chemical from water and provide fast, reliable leak detection performance in industrial environments.
For detailed specifications and applications, please visit the Yoohantech leak detection product page.
Fast Detection Response: When exposed to Surfynol TG, the sensor activates an alarm within 10 seconds, helping operators respond quickly to a leak event.
No Response to Water: Even after more than 60 seconds in water, the sensor shows no reaction, reducing the risk of false alarms caused by moisture or cleaning conditions.
Optimized for Organic Solvents: The YHSP-SA is designed for accurate organic solvent leak detection in industrial applications where selective detection is important.
Adjustable Detection Threshold: The system can be configured with a defined initial value and alarm setpoint to support stable and precise detection performance.
Flexible Installation Structure: The separated sensor and control module design allows installation in narrow spaces, under piping, or near critical process equipment.
This demonstration shows not only the alarm response, but also the stability and measurement logic of the leak detection system through clear test conditions and numeric data.
[Reliability Check] Water Exposure Test (0:47): The sensor is immersed in water for about 60 seconds and shows no response, confirming reliable operation in a non-target liquid.
[Performance Check] Surfynol TG Response Test (2:08): Once the sensor is exposed to Surfynol TG, the measured value changes and the alarm is triggered in less than 10 seconds.
📈 Measured Test Data:
Sensor Model: YHSP-SA (separated electronic point leak detector)
Initial Sensor Value: 1.07
Alarm Setpoint: 1.13
Final Response Time: Approximately 10 seconds
Reliable leak detection requires both sensitivity and stability.
The Yoohantech YHSP-SA leak detector provides fast response to target chemicals and stable operation in non-target conditions, helping improve safety standards in industrial facilities.
We confirm applicability and recommend solutions based on your target liquid and site conditions.
Setting the trusted standard for liquid leak detection in industrial facilities.