Leak Detection Tests

safety, driven by dedication, and delivering innovation.

Yoohantech Co., Ltd.
Normal Octyl Mercaptan (NOM) Leak Detection Test | YHSP-SA Organic Solvent Sensor Response in 3 Seconds
Model
YHSP-SA
Substance Name
Normal Octyl Mercaptan (NOM)
Chemical Formula
C8H18S
CAS No.
111-88-6
Substance Type
Organic Solvent

Video Review 3-Line Summary of the NOM Organic Solvent Leak Detection Performance Test

  • 🧪 Test Model: Organic Solvent Detection Sensor YHSP-SA
  • Detection Speed: Alarm activated within 3 seconds upon contact with the chemical liquid
  • 🚫 Water Response: No response after more than 30 seconds in water, helping prevent false alarms

 

 

3 seconds can make a critical difference in chemical leak safety. This test shows how fast leak detection helps secure valuable response time in industrial environments.

 

Normal Octyl Mercaptan (NOM) leak detection, organic solvent leak detection, and fast chemical leak sensor response are critical for industrial safety in facilities handling hazardous liquids. This performance test shows how the YHSP-SA electronic point leak detection sensor responds quickly and accurately to Normal Octyl Mercaptan (NOM), while remaining unresponsive to water under the same conditions.

In this test, the YHSP-SA sensor is immersed in water first to verify no false alarm, and then tested with Normal Octyl Mercaptan (NOM), where it reaches the alarm setpoint within 3 seconds. This demonstrates a fast and selective response for organic solvent leak monitoring. You can also view more models on the Leak Detection Sensors product page.

 


 

🧪 Leak Detection Test Highlights

 

  1. Accuracy Test: No Response to Water

    • First, the leak detection sensor is immersed in water for 30 seconds to confirm that it does not respond to water. This helps verify stable operation and reduces the risk of false alarms caused by moisture or non-target liquids in the field.

    • Next, in the key test, the sensor is immersed in Normal Octyl Mercaptan (NOM), where it triggers an alarm within 3 seconds after contact.

  2. Fast Leak Detection Performance

    • From the initial sensor value of 1.06 to the alarm setpoint of 3.00, the response time was within 3 seconds. This fast response helps secure critical reaction time when an organic solvent leak occurs.

 

✨ Key Benefits of the YHSP-SA Organic Solvent Leak Detection Sensor

 

Fast response speed: Detects organic solvent leaks immediately and supports rapid initial action in the event of liquid leakage.

  • High reliability: Clearly distinguishes between water and target hazardous liquid, helping minimize false alarms and improve monitoring stability.

  • Clear alarm indication: Enables operators to recognize leak events quickly and respond without delay.

  • Suitable for industrial environments: Designed for practical organic solvent leak detection in chemical handling and process facilities.

 


 

Industrial safety in chemical handling environments cannot be left to chance.

 

The YHSP-SA industrial leak detection sensor provides a fast and reliable solution for detecting Normal Octyl Mercaptan (NOM) and other organic solvent leaks in industrial applications.

 

💧

Liquid Leak Detector: Technical Inquiry

We confirm applicability and recommend solutions based on your target liquid and site conditions.

✉️ Email Us 💬 Request Technical Consultation

Setting the trusted standard for liquid leak detection in industrial facilities.

Yoohantech Co., Ltd.

I want to

Selecte editor

※ Be careful of Refresh

Are you sure to Delete this Comment?

SHARE

Defining the Trusted Standard in Liquid Leak Detection for Industrial Safety.

Yoohantech Co., Ltd.