safety, driven by dedication, and delivering innovation.
Waste DIW leak detection is important in semiconductor, ultrapure water, and industrial wastewater handling environments where stable liquid monitoring and false alarm prevention are critical. This performance test shows how the YHSP-SAR electronic point leak detection sensor responds quickly to waste DIW while remaining unresponsive to water under the same test conditions.
In this test using waste DIW provided by Versum Materials and Hanyang Engineering, the sensor detects the target liquid within 5 seconds. This demonstrates that the YHSP-SAR can be used as a practical solution for industrial liquid leak detection where both fast response and stable selectivity are required. You can also explore more models on the Leak Detection Sensors product page.
⚡ Ultra-Fast Detection
When a leak occurs, the sensor detects the target liquid and activates the leak alarm within 5 seconds. This fast response helps operators secure valuable reaction time and reduce the spread of liquid leakage incidents.
💧 Selective Response with No False Alarm in Water
The sensor does not respond to normal water exposure, allowing it to distinguish between target liquid conditions and non-target water contact. This helps reduce unnecessary alarms and improve process reliability.
🚨 Clear Audio-Visual Alarm
Once leakage is detected, the system provides a clear alarm indication so that operators can recognize the situation quickly and respond without delay.
🛡️ Reliable and Practical for Industrial Use
After detection, the sensor can be cleaned and reused, making it a practical and economical leak detection sensor for industrial liquid monitoring applications.
[STEP 1] Control Test: Water Response Check
Objective: To confirm that the leak detection sensor does not respond to normal water exposure and helps prevent false alarms.
Procedure: The sensor is immersed in water for 30 seconds.
Result: No response. No alarm is triggered, confirming stable operation in water.
[STEP 2] Test Liquid Evaluation: Waste DIW Response Time
Objective: To measure the response speed of the point leak detection sensor to waste DIW.
Procedure: The sensor is immersed in waste DIW.
Result: The alarm is activated in 5 seconds, confirming successful leak detection.
Conclusion: The YHSP-SAR leak detection sensor provides a reliable solution for protecting equipment, facilities, and personnel in industrial liquid leak monitoring applications.
We confirm applicability and recommend solutions based on your target liquid and site conditions.
Setting the trusted standard for liquid leak detection in industrial facilities.
Defining the Trusted Standard in Liquid Leak Detection for Industrial Safety.