safety, driven by dedication, and delivering innovation.

Yoohantech Co., Ltd.
YHSP-SAR Electronic Leak Point Sensor
Yoohantech YHSP-SAR Electronic Liquid Leak Point Sensor for Acids, Alkalis & Inorganic Solutions
No Response to Water Optimized detection by chemical family for acids, alkalis and inorganic solutions.

๐Ÿ’ก Key Summary: Electronic leak point sensor with optimized detection by chemical family for acids, alkalis & inorganic solutions

YHSP-SAR is an electronic liquid leak point sensor designed for chemical-family specific detection of acids, alkalis, and inorganic solutions. It ignores water and detects leaks within 2 to 60 seconds, depending on the chemical. The sensor can be washed with water and reused after thorough drying, helping reduce sensor replacements and maintenance costs. Use it with a YHSM-01S-AR (1-channel) or YHSM-04S-AR (4-channel) leak detection control module.

For Acids, Alkalis & Inorganic Solutions | Optimized Detection by Chemical Family | Controller Module Required
YHSP-SAR

Electronic Leak Point Sensor for Acid, Alkaline and Inorganic Solutions

YHSP-SAR: Optimized detection by chemical family for acids, alkalis & inorganic solutions.

YHSP-SAR is an electronic leak point sensor for the acid, alkaline and inorganic solution chemical family. It ignores water and detects leaks within 2 to 60 seconds, depending on the chemical. It is suitable for indoor and outdoor use around tanks and piping in industrial facilities.

KEY FEATURES

Differentiated Technology (Key Features)

๐Ÿ’ง Optimized Detection by Chemical Family

โ€ข Ignores water and detects chemicals in acid, alkaline and inorganic solution categories. (Typical media include sulfuric acid, hydrochloric acid, nitric acid, hydrofluoric acid, sodium hydroxide and hydrogen peroxide.)

โšก๏ธ Fast Response

โ€ข Detects leaks within 2 to 60 seconds, depending on the chemical.

โ™ป๏ธ Washable & Reusable for Better Cost Efficiency

โ€ข After leak detection, wash the sensor with water and dry thoroughly before reuse. Repeated use helps reduce sensor replacements and maintenance costs.

๐ŸŒ Control Module Integration

โ€ข Use YHSP-SAR with either the YHSM-01S-AR (1-channel) or YHSM-04S-AR (4-channel) leak detection control module for system operation.

๐Ÿ’ช Simple 2-Wire Connection

โ€ข Observe the correct polarity when connecting the sensor: White: positive (+); Black: negative (-).

๐Ÿ“„

Product Downloads

๐Ÿ“ฅ Download Brochure ๐Ÿ“ฅ Download Datasheet
๐ŸŽฅ

Watch Real Leak Detection Test Videos

View test footage verified under real leak conditions, including sensor response and alarm operation.

โ–ถ๏ธ View Leak Test Videos
TECHNICAL SPECIFICATIONS
Item Details
Model YHSP-SAR
Supply Voltage DC 5 V
Measurement Range 0 to 3000
Output Phase Shift
Target Liquids

Chemicals in acid, alkaline and inorganic solution categories

Dimensions 68 ร— 68 ร— 32 (ยฑ0.5) mm
Materials

SUS 304, PP, etc.

Installation Environment

Around tanks and piping in industrial facilities
Suitable for indoor and outdoor use

Operating Temperature -20 to +55 ยฐC
Typical Detection Media Sulfuric acid, hydrochloric acid, nitric acid, hydrofluoric acid, sodium hydroxide, hydrogen peroxide, etc.
Response Time Within 2 to 60 seconds (depending on the chemical)
Sensor Wiring 2-wire sensor: White (+), Black (-)
Key Points โ€ข Chemical family detection: ignores water and detects acid, alkaline and inorganic solutions
โ€ข Fast response: within 2 to 60 seconds (depending on the chemical)
โ€ข Control module integration: use either YHSM-01S-AR or YHSM-04S-AR
โ€ข Washable and reusable: wash with water and dry thoroughly before reuse
โ€ข 2-wire connection: White (+), Black (-)

Industry-Specific Leak Detection Proposals

Semiconductors ยท Petrochemicals ยท Oil Refining ยท Batteries ยท Power Generation ยท Steel ยท Warehousing ยท Wastewater Treatment ยท Defense

๐Ÿญ

View Installation Case Studies

Explore real industrial leak detection installations and get guidance on a configuration that fits your facility.

โœ‰๏ธ Email Us ๐Ÿ’ฌ View Case Studies

ย 

DIMENSIONS (Drawing)

dwg.png

ย 

CONTROL MODULES & OPTIONAL ACCESSORIES

YHSM-01S-AR

๐Ÿ”นYHSM-01S-AR (1-Channel Leak Detection Control Module)

YHSM-04S-AR

๐Ÿ”นYHSM-04S-AR (4-Channel Leak Detection Control Module)

YHWS-P01

๐Ÿ”นYHWS-P01 (Position Marking Base, Optional)

YHBK-P02

๐Ÿ”นYHBK-P02 (Point Sensor Protective Housing, Optional)

Use YHSP-SAR with either the YHSM-01S-AR (1-channel) or YHSM-04S-AR (4-channel) leak detection control module.
YHBK-P02 protective housing and YHWS-P01 position marking base are optional accessories.

ย 


ย 

YHBK-P02 Assembly Example

YHBK-P02 Assembly Example

[Electronic Leak Point Sensor Housing Assembly Example]

ย 

๐Ÿ’ง

Liquid Leak Detector: Technical Inquiry

We confirm applicability and recommend solutions based on your target liquid and site conditions.

โœ‰๏ธ Email Us ๐Ÿ’ฌ Request Technical Consultation

Setting the trusted standard for liquid leak detection in industrial facilities.

Yoohantech Co., Ltd.

I want to

SHARE

Defining the Trusted Standard in Liquid Leak Detection for Industrial Safety.

Yoohantech Co., Ltd.