Leak Detection Tests

safety, driven by dedication, and delivering innovation.

Yoohantech Co., Ltd.
1-Second Sulfuric Acid Leak Detection | 95% H₂SO₄ All-in-One Sensor with Zero False Alarm (YHSM-AR01)
Model
YHSM-AR01
Substance Name
Sulfuric Acid
Chemical Formula
H2SO4
CAS No.
7664-93-9
Substance Type
Acid

Video Review 3-Line Summary of the Sulfuric Acid (H₂SO₄) Leak Detection Performance Test

  • 🧪 Test Model: Acid/alkali dedicated integrated sensor YHSM-AR01
  • Detection Speed: Immediate alarm activation within 1 second (Instant) upon contact with 95% sulfuric acid solution
  • 🔌 Convenience: All-in-One smart sensor with no separate control panel required

 

 

 

[All-in-One] Sulfuric Acid Leak Detector Performance Test! Instant Protection with Near-Zero Delay

 

This video shows a real performance test demonstrating how accurately the innovative integrated leak detector (Model: YHSM-AR01) developed by Yoohantech detects leaks of sulfuric acid (H₂SO₄), one of the most hazardous chemicals used in industrial sites. See the outstanding performance of this essential safety device for chemical leak monitoring.

 


 

## Key Point: Why Choose the Yoohantech Leak Detector?

 

  • ALL-IN-ONE System (0:03): This sensor is an integrated leak detector with a built-in alarm function. Without a separate receiver or control module, the sensor can be used immediately by directly connecting DC 24V power and a beacon light. This helps reduce installation cost and makes maintenance easier.

 


 

## Mission 1: False Alarm Prevention - Water Response Test

 

First, the test checks how well the leak detection sensor distinguishes harmless water such as rainwater or condensation from hazardous chemicals.

  • Procedure (0:42 ~ 1:14): The sensor is placed in a container filled with water and left there for 20 seconds.

  • Fact Check: Even after 5, 10, and 15 seconds, the beacon light connected to the sensor remains completely silent with no response at all. No false alarm occurs.

  • Conclusion: The sensor offers excellent selectivity by not reacting to ordinary water or moisture, helping reduce unnecessary alarms in the field.

 


 

## Mission 2: Immediate Detection of High-Concentration Sulfuric Acid Leakage

 

Next, a real hazard scenario is simulated. While the sensor is still in water, 95% high-concentration sulfuric acid is added to reproduce a leak event.

  • Procedure (1:15 ~ 1:37): Sulfuric acid is dropped toward the submerged sensor using a dropper.

  • Fact Check (1:38 ~ 1:47): The moment the sulfuric acid mixes with water and reaches the sensor, the beacon light flashes and the leak alarm is activated immediately without delay.

  • Conclusion: This sensor detects sulfuric acid quickly and accurately even in a diluted condition mixed with water. In real industrial sites, this means valuable response time can be secured even when leaked chemicals are diluted by surrounding liquids.

 


 

## Final Analysis: A Practical Answer for Chemical Safety Management

 

This test clearly proves that the Yoohantech YHSM-AR01 integrated leak detector is more than just a sensor. It is a smart safety solution that combines easy installation, lower system cost, high stability with no false alarm, and immediate response to hazardous chemicals.

 

💧

Liquid Leak Detector: Technical Inquiry

We confirm applicability and recommend solutions based on your target liquid and site conditions.

✉️ Email Us 💬 Request Technical Consultation

Setting the trusted standard for liquid leak detection in industrial facilities.

Yoohantech Co., Ltd.

I want to

Selecte editor

※ Be careful of Refresh

Are you sure to Delete this Comment?

SHARE

Defining the Trusted Standard in Liquid Leak Detection for Industrial Safety.

Yoohantech Co., Ltd.